Select Page

WhisperKOOL
Mini Ceiling Mount
500 Cubic Feet

$6,719.00

SKU: S-WKCMMINI-220 Categories: ,
  • Offers excellent efficiency by drawing in the warmer air which accumulates at the ceiling, cooling and dispersing the air throughout the environment
  • 2-speed fan switch
  • Hex mesh grille with air filter
  • Flare fittings for easy installation
  • Standard and 24V thermostat options available
  • Includes a pump system to remove excess condensation
  • Includes cold weather start kit
  • Allows for maximum racking space
  • No ducting required
  • 220V High Efficiency (H.E.) Condenser Option

WhisperKool created the Mini Ceiling Mount split system to handle smaller-capacity cellars. In a small environment, you need all the space you can get for racking. Don’t let a cooling unit limit you.

Note: A qualified HVAC-R technician is required for installation. Failure to install the system by a qualified technician will void the warranty.

*PLEASE NOTE: WhisperKOOL does not provide a smart thermostat. By selecting the 24V Thermostat Conversion Kit, you have acknowledged that the system will not be built with the standard WhisperKOOL control or liquid measuring bottle probe. To run the equipment, you will have to source and purchase your own 24V smart thermostat. The WhisperKOOL Customer Satisfaction Team does not provide technical support for smart thermostats.

2084 – 3288

The BTU/h value range shown here is a theoretical number. There are often circumstances under which a cellar design may require a larger unit due to variables not accounted for in the formula. For example, these variables could be building materials (such as glass, stone, concrete, etc.) which do not offer the insulation capacity required to maintain the optimal cellar environment. We recommend purchasing a unit with a larger capacity to compensate for these unaccounted-for variables. An undersized unit can lead to premature failure and will most likely prevent the cellar from reaching your desired temperature.

 

110V
Cellar Size
500 cu. ft.*
BTU/h (85°F condenser air intaketemperature)
Low: 1950 • Med: 2167
CFM 107
Dimensions Evaporator: 25.05” L x 11.34” W x 11.17” H • Condenser: 13.97”L x 15.85”W x 9.86”H
Refrigerant R-134a
HP 0.7
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required) • Condenser: 115V (15 amp dedicated circuit required)
Weight (lbs) Evaporator: 40 • Condenser: 38.8
Amps Evaporator: 1 (running amps) • Condenser: LRA 26/RLA 4.4
Line Set Liquid Line 1/4” • Suction Line (Less than 50ft. 3/8”) (Greater than 50ft. 1/2”)
Drain Line ¼” ID clear plastic tubing (not provided)
Installation Evaporator is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable )
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)

220V
EVAPORATOR
Cellar Size
500 cu. ft *
Fan Speed
Low Medium
BTU/h
(60°F condenser air intake temperature) Sensible / Total – 2442 / 3131
BTU/h
(75°F condenser airintake temperature) Sensible / Total – 2132 / 2592 
BTU/h
(85°F condenser air intake temperature) Sensible / Total – 2084 / 2514
Dimensions
22.05”L x 11.08”W x 11.34”H
Refrigerant
R-134a
Voltage Rating
120V (15-amp dedicated circuit required)
Weight (lbs)
35
Amps
0.64 (Running Amps)
Drain Line
1/4″ ID clear plastic tubing (not provided) – Rigid tube recommended
Installation
Evaporator unit is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat
Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V – customer supplied
Temp. Delta
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty
Two-year limited warranty (parts and labor)

CONDENSER
dBA 48
Dimensions
31.18″L x 10.75″W x 21.18″H
Condensing Unit HP
0.35HP
Voltage Rating
220V (15-amp dedicated circuit required)
Weight (lbs)
51
Amps
LRA 5.3A, RLA 1.55A, FLA 1.7A
Line Set
Liquid line 1/4” OD; Suction line 3/8” OD (less than 50 ft.), 1/2” (greater than 50 ft.)
Installation
Evaporator unit is installed in the cellar. The condensing unit is installed up to 100 line feet from the evaporator unit.
Temp. Delta
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Warranty
Two-year limited warranty (parts and labor)