Select Page

WhisperKOOL
Platinum Split 8000
Ducted
1750 Cubic Feet

$7,489.00

SKU: S-WKPS8000-220-FD Category:
“Virtual Silence”

  • Quiet and efficient operation
  • Flare fittings for easy installation
  • 2-speed fan switch to adjust BTU/h capacity
  • Standard and 24V thermostat options are available
  • Condensing unit can be placed outdoors with the purchase of exterior housing
  • Includes a pump system to remove access condensation
  • 55°F temperature differential between cellar and condensing unit air intake temperature
  • 220V High Efficiency (H.E.) Condenser Option

A Ducted Split system has more installation options than a self-contained system. The unit may be installed up to 25 ducted feet from the cellar, with the cool air flowing to the cellar and the heat exhaust ducted to the outside of the home. Ducting is also a more aesthetic choice for wine collectors who do not want to see a cooling unit in the cellar. Noise from the unit will be reduced or eliminated, depending on the installation.

Described in the simplest terms, a split system is a cooling unit wherein the evaporator unit and condensing unit have been “split” into two separate units instead of being contained within the same housing. The evaporator unit is located in or near your cellar, and the condensing unit is generally located outside, or in an attic or utility room.

The Ducted Platinum Split 8000 allows you to decide where the evaporator unit and the condensing unit will be located. The condensing unit can be located up to 100 ft. away from the evaporator unit. The evaporator unit will be mounted in the cellar or it can also be located nearby with ducting.

Not sure if the Platinum Split is suitable for your wine cellar? Call 800-323-3130.

Note: A qualified HVAC-R technician is required for installation. Failure to install the system by a qualified technician will void the warranty.

*PLEASE NOTE: WhisperKOOL does not provide a smart thermostat. By selecting the 24V Thermostat Conversion Kit, you have acknowledged that the system will not be built with the standard WhisperKOOL control or liquid measuring bottle probe. To run the equipment, you will have to source and purchase your own 24V smart thermostat. The WhisperKOOL Customer Satisfaction Team does not provide technical support for smart thermostats.

3073 – 4798

The BTU/h value range shown here is a theoretical number. There are often circumstances under which a cellar design may require a larger unit due to variables not accounted for in the formula. For example, these variables could be building materials (such as glass, stone, concrete, etc.) that do not offer the insulation capacity required to maintain the optimal cellar environment. We recommend purchasing a unit with a larger capacity to compensate for these unaccounted-for variables. An undersized unit can lead to premature failure and will most likely prevent the cellar from reaching your desired temperature.

110V
Model
8000
Cellar Size 1750 cu. ft.*
BTU/h (85°F condenser air intake temperature) Medium: 3788 • High: 3879
CFM 200
Dimensions Evaporator: 16.1”L x 20.5”W x 15.5”H • Condenser: 16.08”L x 16.23”W x 12.61”H
Refrigerant R-134a
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required) Condenser: 115V (20 amp dedicated circuit required)
Weight (lbs) Evaporator: 57 • Condenser: 66
Amps Evaporator: 1 (running amps) • Condenser: LRA 50/RLA 9.3
Line Set Liquid Line 1/4” • Suction Line (Less than 50ft. 1/2”) (Greater than 50ft. 5/8”)
Duct Size 8” Supply • 10” Return
Drain Line ½” ID clear plastic tubing (not provided)
Installation Evaporator can be installed up to 25 duct feet away from the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)
Options: Exterior condenser housing, 24V thermostat conversion kit, condenser coil coating

220V
EVAPORATOR

Model 8000
Cellar Size 1000 cu. ft *
Fan Speed Medium | High
BTU/h (60°F condenser air intake temperature)  4814 / 5687 | 5133 / 5777 Sensible / Total
BTU/h (75°F condenser air intake temperature)  4455 / 4997 | 4607 / 5012  Sensible / Total
BTU/h (85°F condenser air intake temperature)  4370 / 4834 | 4577 / 4982 Sensible / Total
dBA 56 | 62
Dimensions 16.1”L x 20.5”W x 15.5”H
Refrigerant R-134a
Voltage Rating 120V (15-amp dedicated circuit required)
Weight (lbs) 54
Amps 2.2 (Running Amps)
Drain Line 1/2″ ID clear plastic tubing (not provided)
Installation Evaporator unit is installed in the cellar.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (retractable cable), 24V – customer supplied
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)

Condenser
Fan Speed Medium | High
dBA 48
Dimensions 31.18″L x 10.75″W x 21.8″H
Condensing Unit HP 0.7 HP
Voltage Rating 220V (15-amp dedicated circuit required)
Weight (lbs) 56
Amps LRA 13.2, RLA 3.19, FLA 3.66
Line Set Liquid Line 1/4” OD • Suction Line (Less than 50ft. 1/2” OD) (Greater than 50ft. 5/8” OD)
Installation Condensing Unit can be installed up to 100 line feet from evaporator unit
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)