CellarPro 3200VSx-ECX
Cooling Unit (Exterior)800 Cubic Feet
#1654

$4,395.00

Free Shipping
*Shipments to AK and HI – Please call for a quote

3040 BTUH @ 55°F.
CellarPro’s 3200VSx cooling units (1/3 Ton Nominal) are suitable for external installations from 20°F to 115°F in residential and commercial wine cellars up to 800 cubic feet. The 800 cubic feet cellar size assumes that the cellar is constructed with insulation of R19 or better in all walls and ceiling (ie no glass or uninsulated concrete), the cooling unit is not ducted, a setpoint of 55°F inside the cellar and ambient temperatures up to 85°F outside the cellar.

Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions more effectively than similar units from competing brands. 3200VSx units also are significantly quieter than comparable units from other brands.

3040 SENSIBLE BTUH @ 55F.
CellarPro’s 3200VSx-ECX cooling units (1/3 Ton Nominal) are engineered for external installations from 20F to 110F in residential and commercial wine cellars up to 800* cubic feet .

Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110F more effectively than similar units from competing brands. 3200VS units use energy-efficient EC fans and are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.

*Assuming R19 insulation throughout the cellar, 55F inside the cellar and 85F outside the cellar. Cold-side ducting, glass and/or uninsulated walls, extreme humidity, altitude and other factors may affect the sizing calculation.

Please note: Our units were not designed for, and our warranty does not cover damage from, marine exposure (within 5 miles of the ocean). In these environments, you will need an applied coating, such as Insitu®, to protect against corrosion that is common in coastal regions.

Our cooling units are designed to be used in properly-constructed wine cellars that are adequately insulated, airtight and sealed with a vapor barrier. In improperly-constructed cellars, the cooling unit will create excess condensation, leading to damage and premature failure of your cooling unit (not covered by warranty).3040 SENSIBLE BTUH @ 55F.
CellarPro’s 3200VSx-ECX cooling units (1/3 Ton Nominal) are engineered for external installations from 20F to 110F in residential and commercial wine cellars up to 800* cubic feet .

Performance testing shows that this unit maintains optimal cellar temperature and humidity conditions in extreme conditions up to 110F more effectively than similar units from competing brands. 3200VS units use energy-efficient EC fans and are significantly quieter than comparable units from other brands. Visit our Learning Center for data tables, performance charts and product comparisons among different brands.

*Assuming R19 insulation throughout the cellar, 55F inside the cellar and 85F outside the cellar. Cold-side ducting, glass and/or uninsulated walls, extreme humidity, altitude and other factors may affect the sizing calculation.

Please note: Our units were not designed for, and our warranty does not cover damage from, marine exposure (within 5 miles of the ocean). In these environments, you will need an applied coating, such as Insitu®, to protect against corrosion that is common in coastal regions.

Our cooling units are designed to be used in properly-constructed wine cellars that are adequately insulated, airtight and sealed with a vapor barrier. In improperly-constructed cellars, the cooling unit will create excess condensation, leading to damage and premature failure of your cooling unit (not covered by warranty).

Configurations

  • CellarPro 3200VSx-ECX units are self-enclosed, fully-charged units designed to be installed through an external wall and sized to fit in between standard wall studs.
  • 3200VSx-ECX units can be located remotely from the cellar with the addition of one of our front duct packages (however, the entire unit cannot be located in an external environment). Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our cold-side duct packages allow these cooling units to be ducted up to 50 equivalent feet away from the cellar and requires 8-inch (or greater) ducting from start to finish.
  • When calculating equivalent feet, each 90-degree turn counts for 8 feet.
  • For remote or inaccessible installations, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
  • 3200VSx-ECX units require fresh air intake at the rear of the cooling unit, and are designed to handle shaded environments ranging from 20F to 110F.
  • For installation in environments below 20F down to -20F, it will be necessary to add our Fan-Cycling Switch (P/N 6972).
  • The front of the cooling unit should never be exposed to temperatures below 32F.
  • A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.
  • We ship these units strapped to a pallet via common carrier with curbside delivery. Inside delivery is available for an additional charge.

Brand: CellarPro

UPC: 077757016547

Size: 14 1/2w x 27 3/5d x 19 7/10h (in)

Weight: 140 lbs

Power/Rating:
115V AC / 60 Hz
Compressor Amps:
– Startup: 30.0 Amps
– Unit Amp Rating: 9.3 Amps (high fan speed)
– Compatible with Dedicated 15-Amp Circuit
BTUH @ 55F:
– Low Fan Speed: 2487
– Medium Fan Speed: 2876
– High Fan Speed: 3040
– 1/3 Ton Nominal
– Total Watts: 500 (med fan speed)

 

 

Click on one of the following links for more information:

WARNING - This product can expose you to chemicals including Lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Cold Temperature

  • Compressor Heater #1727: protects the unit when installed in environments that drop below 40F down to 20F – INCLUDED.
  • Fan Cycling Switch #6972: supports the unit in temperatures below 20F and as low as -20F when combined with our compressor heater.


Duct Hoods

  • Duct Hoods (Cold Side) (#7408 for low-humidity environments or #7427 for high-humidity environments) and Kits (#1476 for low-humidity environments or #7426 for high-humidity environments): permits the cooling unit to be located remotely, up to 50 equivalent feet away from the cellar.
  • Duct Kits are the same as Duct Hoods, and also include 2 x 25-feet of 8-inch insulated (R-6) flex ducting.


Extended Mounting Bracket

  • For retrofit installations where the wall opening is too big for our cooling unit, use our Extended Mounting Bracket on one or both sides to plug the opening.


Filters & Grills

  • Use our filter & grill guide to find the cooling unit filter or duct filter and/or duct grill that is appropriate for your cooling unit.


Remote Thermostats, Displays & Probes

  • Networkable Thermostats #27346 and #27310: connect your cooling unit to a networkable, wi-fi enabled thermostat (sold separately). Must be ordered at the same time that the equipment is ordered. Other limitations apply – read the networkable thermostat description for more information. Includes 10 feet of wiring.
  • Remote Display #1603: lets you place the digital panel wherever you want, whether inside or outside the cellar. Includes 10 feet of wiring.
  • Remote bottle Probe #1434: this remote probe with a 10-foot cord overrides the probe on the face of the cooling unit, and allows it to monitor air or liquid temperatures at various locations inside the cellar.
  • Extension cords available in 25-foot (#1780) and 50-foot (#1781) lengths.

DID YOU KNOW?
Nobody protects your wine cellar better than CellarPro Cooling Systems! In the event your cooling unit fails and the failed components are covered by our warranty, we’ll send a replacement cooling unit to you per the terms of our Replacement Unit Program

CellarPro Replacement Unit Program
If your CellarPro cooling unit fails and the parts that failed are still covered by warranty, we’ll send a replacement cooling unit to you, as follows:

  1. Your cooling unit must be registered at CellarPro
  2. Your cooling unit must have been properly sized, installed and maintained
  3. Your cooling unit may not have been permanently modified, damaged or disfigured

Please note:

  • Replacement units are factory-refurbished cooling units with a similar build date as your original unit
  • You are responsible for the shipping cost to send the replacement unit to you and return the original unit to us, and the cost (if any) to remove the original unit and install the replacement unit
  • In order to send a replacement unit, we require a deposit, which will be refunded minus shipping costs upon the return and pending the inspection of the original unit
  • If the original unit failed due to improper intallation or use, the failure is not covered by warranty and we will deduct the cost of the repairs from the refund of your deposit.